top of page
busung

Mortuary refragerators

Updated: May 16


MORTUARY REFRIGERATORS FEATURES & FABRICATION SPECIFICATION SHEET  Busung Freezer Industrial Co., Ltd.

 

Delivery lead time: Within 2 months from the time of contract

Mortuary refrigerators
Mortuary refrigerators
Mortuary refrigerator
Mortuary refrigerator

3. Fabrication Specification sheet

3-1 Sheet metal

1)   The product must be made of sheet metal that matches the production drawings and

 general specifications confirmed after the contract.

2)  Ensure that there is no error of ±0.5mm or more in the instrument

specifications, excluding the thickness of SUS plate. The finished product must meet the

 layout specifications on the building plan.

3)   Corners and joints must maintain exact right angles or intended angles.

4)   Due to the nature of the mechanism, instruments that do not require plate joints must

 be manufactured from sheet metal without cutting the original plate.3-2 Cutting

 and bending

1)   It must be cut and bent in the correct position based on the sheet metal marking line.

2)   The principle of cutting and bending is to bend once at a time, but the corner angles

 must  be completely right angles, and the front side must beR20 or bent at a right

 angle, making it easy to use.

3)  Comply with the indicated standards and prevent cutting and bending errors of ±2mm

 or more to ensure that the right angle and level with the connecting device are perfectly

 maintained.

Mortuary refrigerators installation
Mortuary refrigerators installation

3-3 Welding

1)   All welding of stainless steel is argon welding, and welding rods of the same or higher

quality as the base material must be used, but the high bead must prevent the welded

 material from melting, and the joint at the connection must be smooth after one welding.

2) If connection is unavoidable due to the specifications of the Stainless steel plate,

 it should be butt joint welded, and the finished surface after welding should be close

 to the original plate.

3)   Parts that do not require welding on the entire surface must be spot welded.

4)   There must be no cracks or other defects due to excessive welding, and the product

 must be welded so that the angle is correct.

3-4 Polishing and finishing

1)   The welded protruding part due to welding must be polished beautifully after the joint 

are a has been polished without marking.

2)   After polishing, all exposed surfaces must be hair lined and finished with sand paper

 in the same manner as the original plate without gloss.

3)   Edges and cut parts must be finished with sand paper to remove sharp edges

 generated during cutting to avoid damaging body parts when using the tool.

Mortuary refrigerator installation
Mortuary refrigerator installation

3-5 Assembly condition

1)   Depending on its functional characteristics and use, the device must be 

assembled  with strong reinforcement materials so that its original shape is not 

deformed or damaged even when used for a long time.

2)   Opening parts such as the body stand and door must be assembled so that they can

 be opened and closed smoothly at 180 degrees, with little shaking and minimal noise.

3)   When assembling the device, assemble it on a flat surface to maintain levelness. When

installing, assemble the parts in contact with each other so that they are perpendicular

 and level to prevent gaps.

4)   The lower part of the workbench must be attached to a shelf, except in special cases 

for functional purposes, and must be assembled so that the adjustable feet do not move.

5)   When assembling electrical equipment, the purpose of use and on-site installation

 conditions must be thoroughly reviewed, and then parts must be confirmed before

 installation.

6)   Mobile devices must use wheels with sufficient strength and mechanical and physical

 excellence to be able to transport and move even when used for long periods of time.

Mortuary refrigerator the inside
Mortuary refrigerator the inside

3-6 Inspection and operation

1)   Products that have been manufactured must be self-inspected for complete performance 

and functionality.

2)   Electrical appliances and refrigerators are delivered after confirming that there are no 

problems with heat conduction, cooling capacity, insulation status, etc. after self-testing.

Mortuary refrigerator package carrying
Mortuary refrigerator package carrying

3-7 Materials used (applicable to the entire device)

1)   For products or parts for which foreign specifications are not specified,in

  principle, K.S type approved products should be used. However, due to the

 nature of the mechanism, if there are no K.S type parts, domestically produced

 products of the highest quality will be used. Parts not specified in the general

 specifications and drawings will be resolved after consultation with the contractor use.

2)   The material of the metal parts inside the front, rear, left, right, upper, and lower sides

 of all devices must be 27 types of stainless steel (STS304 and similar or higher) 

and pipes, and the thickness must be sufficient for the performance of the device. 

The left, right, and rear exteriors use stainless steel, and the front exterior uses 

STS304 (27 types of stainless steel).

2 Body mortuary refrigerators
2 Body mortuary refrigerators

1)   As for the specifications of wires used in electrical appliances, etc., K.S type approved

 products must be used with appropriate capacity in accordance with the electrical wiring

  regulations and related laws to prevent a voltage drop of less than 2% due to the load

 current of the equipment.

2)   Adjustable feet must be height-adjustable by ±25mm or more to enable horizontal

installation on a sloped floor.

3)   The name PLATE is made of acrylic, so A5 paper can be used.

2 Body mortuary refrigerator installation
2 Body mortuary refrigerator installation

** General Fabrication Specification sheet

Article 1 This production intends to apply the “specification” for the production and 

purchase of a body storage refrigerator.

Article 2 Matters not specified in the specifications and general specifications must be

 discussed with the ordering party.

Article 3 The ordering party and the manufacturer must discuss all matters.

Article 4 A production schedule and detailed plan for the overall process must

 be  established in accordance with design books and specifications and in

 consultation with the field supervisor, and production and purchase must

 be carried out according to the scheduled schedule.

Article 5 The contractor must take pre- and post-contract installation photos at the same

 location and submit two copies upon completion so that the before and after

 photos can be compared.

Article 6 The contractor shall provide facilities for on-site inspection, implementation

 equipment, and labor to ensure that there is no disruption to funeral work.

Article 7 When using land near the site, the contractor must use it after prior consultation

 with the ordering party and must restore it to its original state or clean it up after 

use.

Article 8 The contractor must make sufficient preparations in advance to prevent damage to

 the entry and exit of users and vehicles during installation, and if damage occurs, 

agree to restoration or compensation for damage.

Article 9 The contractor shall have an on-site agent or safety manager provide safety training

  to workers and technicians working at the installation site before work and make 

every effort to manage safety. If damage or a safety accident occurs due to

 negligence in installation, all civil servants shall be responsible. Criminal liability and 

restoration or compensation for damages must be discussed.

Article 10 If it is necessary during production and consultation with other types of work is

 necessary, consultation with the ordering party must be made in advance.

Article 11 For installation, a sample must be presented to the ordering party for inspection

 before being brought in to the site, and if there is a manufacturing error or inferior

quality material is selected, it must be remanufactured in consultation with the 

ordering party.

Article 12 If there is a significant difference in on-site circumstances and conditions,

production may be changed or settled.

Article 13 When an increase or decrease in quantity occurs due to on-site circumstances,

 production changes or settlement may be made.

Article 14 During the production and construction, the ordering party may order production

 to be stopped or postponed due to unavoidable circumstances, or the contract 

may be canceled, and compensation for damages resulting from this may not 

be claimed.

Article 15 The contractor may conduct various tests with the ordering party and must 

submit the results to the ordering party.

Article 16 Even if matters are not specified in the design book, minor matters that  naturally 

require production due to site circumstances or nature will be handled in 

consultation with the ordering party and contractor.

Article 17 Fastening devices must be manufactured and installed after consultation with 

the ordering party.

Article 18 The defect repair period for this production is 2 years after production and 

installation.

  

** Reference Korean law related to Hygiene Management Standards for Funeral Homes, etc.

 

Article 20-2 (Hygiene Management Standards for Funeral Homes, etc.) 

Details regarding the hygiene management standards that funeral home business 

operators must comply with in accordance with Article 29, Paragraph 2 of the Act 

and facilities, equipment, and safety standards in accordance with Article 26-4, 

Paragraph 2 of the Decree. The standards are the same as Table 1-3.

[Appendix 1-3] 

Hygiene management standards and detailed standards for facilities, equipment, and safety standards for funeral homes (related to Article 20-2)

Mortuary refrigerators installation
Mortuary refrigerators installation

1.   Classification of funeral home facilities and equipment

a)   Facilities for storing the body, enshrining, burying, transporting, etc.

b)   Facilities for the bereaved family to receive condolences or hold a funeral, and

convenience facilities for mourners

c)   Facilities and convenience facilities for overall management of the funeral home, 

including funeral consultations

d)   Emergency disaster and safety management facilities

2.   Sanitation management and facilities/equipment standards

2-1 common standards

1)   The funeral home must be equipped with appropriate lighting and lighting 

facilities, and use interior and exterior materials to prevent noise. It must be used to 

maintain a reverent and pleasant atmosphere.

2)   Facilities include moisture-proofing, insect-proofing, ventilation, cooling and heating,

 cleaning, waste management, disinfection and sterilization, etc. Safety measures to

 prevent health and hygiene hazards must be prioritized.

3)   Vacuum cleaners must be equipped for water collection and dust collection.

 

2-2 Standards for each funeral home facility/equipment

1)   Facilities for storing, enshrining, burying, transporting the body, etc.

a)   A mortuary room and a mortuary room must be installed, and a body chemical

processing room (including chemical storage facilities), an observation room, and a 

funeral room can be installed.

b)   The mortuary is used to prevent the decay of the body and the propagation of

 infectious agents such as viruses and bacteria. It must be equipped with freezing and 

refrigeration facilities for storing the body 

(hereinafter referred to as "morning refrigerator"),

  At least two single-person mortuary refrigerators are installed to store bodies that

  have died from infectious diseases. Must be equipped separately. However, in the 

case of public funeral halls, in addition to the above facilities, At least two additional

  mortuary refrigerators must be installed to store unclaimed bodies.

c)   The morgue is designed to prevent the decay of the body and the spread of infectious

  agents such as viruses and bacteria. An emergency generator must be provided to

 maintain the temperature below 4℃ at all times. However, this may be excluded if there 

is an electricity supply facility in preparation for an external power outage.

Mortuary refrigerators installation and connecting
Mortuary refrigerators installation and connecting